Electplus Industry Sdn Bhd added new photo in Rubber Insulated Cable - H05RN-F
Apr 11, 2020 at 12:40 pm —
Electra Cables 300/500V H05RN-F (Neoprene / Rubber Cable)

Electra Cables 300/500V H05RN-F (Neoprene / Rubber Cable)

Electra Cables 300/500V H05RN-F  Neoprene / Rubber Cable Application Light duty rubber cable, used for medium mechanical loads in dry areas. Suitable for household, kitchens, offices and workshops (for inst. tailoring) for smaller electrical devices (washing-machines, vacuum-cleaners, irons, household appliances, soldering sets etc.) and mobile devices operating in heavier conditions, such as light industrial and agricultural machines. Ozone-resistant, allowed contact with oils and greases.     Construction    Conductor material: bare copper Conductor construction: fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 Insulation: Ethylene-propylene rubber (EPR) compound, EI4 acc. to DIN VDE 0282 part 1 Outer sheath: EM3 Rubber compound acc. to. DIN VDE 0282 part 1 Sheath colour: black     Technical data   Maximum temperature at conductor, °C: +60 °C During installation temperature, °C: -25 - +60 °C Short circuit max. temperature (5s): up tp 200 °C Bending radius, fixed installation: 15 x OD Nominal voltage Uo/U: 300/500V Test voltage: 2000V Insulation resistance: 20 MΩ/ km Minimal inner bending radius, fixed installation: 6 x OD Flame retardant: IEC 60332-1-2 Ozone resistance: acc. to DIN VDE 0472 part 805 Approval: VDE approved cable read more
Electplus Industry Sdn Bhd added new photo in Rubber Insulated Cable
Apr 11, 2020 at 12:10 pm —
Electra Cables 450/750V H07RN-F (Neoprene / Rubber Cable)

Electra Cables 450/750V H07RN-F (Neoprene / Rubber Cable)

Electra Cables 450/750V H07RN-F (Neoprene / Rubber Cable) Application Used for medium and heavy mechanical loads, in dry and wet areas, also outdoor. Could be installed  under or on plaster, in rocks, concrete, but not in pre-stressed concrete. Cable suitable for fixed industrial and home installation, for operating conditions with possible fire or explosion hazard, for mobile energy users, machine tools and agricultural machines, for construction sites at medium mechanical loads, for large kettles, heating plates, hand lamps, electrical tools such as drills,  circular saws and electrical tools for household use, same as for generator engines or machines on construction sites and craftsman i.e. agricultural plants. Permitted fixed laying on crane and machine elements etc. Permitted voltages up to 1000 VAC at protected laying in tubes or devices, and as connecting rotor cable for engines. Also suitable for cooling installations. Resistant to oil, ozone and UV irradiation. Construction Conductor Bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 Insulation Ethylene-propylene rubber (EPR) compound, EI4 acc. to DIN VDE 0282 part 1 Cores identification by colours according to colours list. Outer Sheath EM2 Rubber compound acc. to. DIN VDE 0282 part 1 Sheath colour Black Technical Data Normal operating temperature  -25 °C up to +60 °C Max. operating temperature 85°C Short circuit max. temperature 5s up to 200 °C Nominal voltage Uo/U = 450/750V Insulation Resistance 20MΩ/ km     Minimal inner bending radius   For fixed installation 6D (D is maximum cableouter diameter) Flame retardant IEC 60332-1-2 Ozone resistance acc. to DIN VDE 0472 part 805 Approval VDE approved cable     Number of core Core colour marking  acc. to VDE 0293-308        2 Blue & Brown        3G Blue, Brown & G/Y        4G Grey, Black, Brown & G/Y        5G Grey, Black, Blue, Brown & G/Y Above 5 core Black insulation with white number coded and G/Y. read more
Electplus Industry Sdn Bhd added new photo in Infra Structure Cables
Feb 7, 2020 at 03:55 pm —
DRAKA Fire Alarm Screen Cable CU/MGT/XLPE/OSCR/LSHF-AT-AR-UV  500V TO IEC332-3-22 SS299-1/BS6387 Cat.CWZ

DRAKA Fire Alarm Screen Cable CU/MGT/XLPE/OSCR/LSHF-AT-AR-UV 500V TO IEC332-3-22 SS299-1/BS6387 Cat.CWZ

DRAKA Fire Alarm Screen Cable CU/MGT/XLPE/OSCR/LSHF-AT-AR-UV  500V TO IEC332-3-22 SS299-1/BS6387 Cat.CWZ Application Draka fire performance cables are specifically designed to facilitate the quick and orderly evacuation of the buildings occupants in the events of an emergency. Purpose designed to maintain circuit integrity to a host of critical safety systems, including fire alarms, emergency lights, CCTV systems and emergency power supplies.   Cable Structure & Features Conductor material (CU) Plain annealed stranded circular copper conductor, Class 2 Fire proof layer (MGT) Mica tape to IEC60331-21/SS229-1/BS6387 Insulation (XLPE) Cross-linked polyethylene, XLPE Pairing / Twining Two/Three/Four insulated cores are cabled together and covered with a polyester tape wrapping Overall Screen (OSCR), Min. 20% overlap of aluminium backed polyester tape in contact with 0.5mm² (16/0.20mm) tinned annealed drain wire followed by a polyester tape wrapped over the screening tape Outer sheath (LSHF-AT-AR) Low smoke zero halogen compound with anti-termite and anti-rodent additives and UV stabilizer.     Applicable standards   Design standard: Conductor standarf: Flame propagation: Fire integrity: Acid gas emission: Smoke emission: IEC 60502-1 IEC 60228, BS 6360 IEC 60332-3-22 IEC 60331-21, SS299-1/BS6387 Cat. CWZ IEC 60754-2 IEC 61034 Technical Data Sheath colour Orange or Red Core identification 1-pair : Black, White Multipair : Black, white with pair numbering (on each core) 1-trial : Black, White, Red Multi-trial : Black, White, Red with trial numbering (on each core) Printing Yes Rated voltage 500V Min. insulation Resistance @ 20ºC 1000MΩ.km Test voltage 2KV/1 min Max. conductor temperature 90°C read more
Electplus Industry Sdn Bhd added new photo in Fiber Optic Cables
Feb 7, 2020 at 03:37 pm —
Fiber Optic Cables

Fiber Optic Cables

Fiber-optic Cables Application As backbone in LAN’s for  premises wiring indoor and outdoor in ducts  internal wiring. Cable Structure & Features General:This specification covers a series of cables with 2 to 24 fibers. The cables consist of tight-buffered 900 mm fibers in a commonsheath. The UV established sheath makes the cables suited for outdoor use. The cables having a state of the art LSHF sheath fulfill environment requirements for today’s cables. The cables fulfill the fire performance tests of IEC 60332-1 The versions of the cables with up to 12 fibers fulfill IEC 60332-3C as well. The cables have the following designation according to DIN/VDE:I-V (ZN) H 2..24. Cable construction Optical fibers: For optical  fiber properties and performance please see the appropriate Fiber Specif ication. The 900mm tight buffered fibers are individually colored for identification: The color code is given in:  “General Information: Fiber colors and color coding” B07. Cable core The fibers are bundled wit h aramid yarns to form the core. Sheath The nominal  thic kness of the LSHF Technical Data The sheathing material complies with a number of national and International standards such as: Cenelec: HD 624.7 S1 DIN/VDE 819 teil  107 The properties of the LSHF material and given in general Information B05. Cabl e properties The physical  properties of the cable are given in table 1 over leaf. read more
Electplus Industry Sdn Bhd added 4 new photos in Onshore Power & Instrumentation Cables
Feb 7, 2020 at 10:39 am —
DRAKA Instrument Cable - LSHF Individual Screen Armoured(SWA)   CU/XLPE/ISOS/LSHF/SWA/LSHF-AT-AR 500V to BS EN50288-7 IEC332-3-22
DRAKA Instrument Cable - LSHF-Overall Screen-Armoured(SWB) CU/XLPE/OSCR/LSHF/SWB/LSHF, 500V to BS EN 50288-7, IEC332-3-22
CSEP Instrument Cable Flame Retardant (Non-Armoured) CU/XLPE/OSCR/PVC-FR (Aluminium Foil Screen Cable)
DRAKA Instrument Cables - LSHF - Overall Screen - Armoured(SWA) CU/XLPE/OSCR/LSHF/SWA/LSHF, 500V to BS EN 50288-7, IEC332-3-22
Electplus Industry Sdn Bhd added 3 new photos in Bus Cables
Feb 6, 2020 at 06:17 pm —
FABER® bus cable AS-Interface
PROFIBUS CABLE
PROFIBUS L2/FIP (Violet)
Electplus Industry Sdn Bhd added new photo
Feb 6, 2020 at 06:08 pm —
FABER KABEL Special Rubber Single Core Cable NSGAFOEU 1.8/3kV

FABER KABEL Special Rubber Single Core Cable NSGAFOEU 1.8/3kV

FABER KABEL Special Rubber Single Core Cable NSGAFOEU 1.8/3kV Application The rubber single-core cable NSGAFOU is a real multi-tasker: Apart from its standards-compliant use as a machine control cable in buses and rail vehicles, it is often used in switchgear as a connecting cable. This special rubber single-core cable is, however, also utilised in other dry rooms. Cable Structure & Features CPR-performance Eca Standard VDE 0250 t.602 Conductor material Tinned copper Conductor construction Class 5 = flexible Core insulation Rubber (EPR) 3G13 Outer sheath Rubber (CR) 5GM3 Flame-retardant VDE 0482-332-1-2 / IEC 60332-1-2 Oli-resistant yes Ozone-resistant yes Sheath colour Black Printing YES     Special Features / Remarks       Cables with 3kV operating voltage in low voltage facilities up to 1000V are classified as short circuit and earth leakage protected connection Free from lacquer damaging substances and silicone (during production) Conform to RoHS Conform to 73/23/EWG - Guideline CE Technical Data Standard Acc. to  DIN VDE 0 250 part  602 Rated voltage Uo/U 1.8/3 KV Testing voltage 6Kv Current carrying capacity Acc. to DIN VDE refer to Technical Guideline Min.bending radius fixed 5 x d Min.bending radius moved 5 x d Operating Temperature Fixed: - 40°C /  +80°C Moved: -25°C /  +80°C Temp. at  conductor Burning behavior +90°C Burning behavior Self-extinguishing and flame-retardant acc. to IEC 60332-1 read more
Electplus Industry Sdn Bhd added 3 new photos in High Temperature Cables
Feb 6, 2020 at 05:27 pm —
FABER KABEL Silicone Insulated Cable 300/500V SIF
FABER KABEL Silicone Screen Cable 300/500V SiHFC-Si-J/O
FABER KABEL Silicone Cable 300/500V SIHF-J
Electplus Industry Sdn Bhd added new photo in Flexible Control Cables
Feb 6, 2020 at 02:58 pm —
FABER KABEL H05Z-K/H07Z-K (Single core Halogen free Cable)

FABER KABEL H05Z-K/H07Z-K (Single core Halogen free Cable)

FABER KABEL H05Z-K / H07Z-K  Single core halogen free cable Application Halogen free and environmentally  single core for internal wiring of devices as well as protected laying within and on shiners. Laying within pipes on-wall and in-wall permitted for signal facilities.. Cable Structure & Features Conductor material Bare copper conductor,  fine wired strande Conductor class Class 5.  acc. to  IEC 60228 /HD 383 / DIN VDE 0295 Core insulation Halogen - free special compound Core colour Black (BK). Red, Yellow (YEL), Light Blue, Dark Blue, Green/Yellow (G/Y), Grey, White (WH)Brown (BRN), Orange (ORG), Violet (VL)     Special Features / Remarks   Largely  resistant to   acids, bases and   usua l oils Halogen free and  flame-retardant No direct laying on pallets, in channels or trays (exceptional as potential compensat  ion) Conform t o   RoHS Conform to 73/23/EWG - Guideline CE Technical Data Standard approvals DIN VDE 0281 part3/HD21.3 S3 HAR  HAR  Rated voltag H05Z-K 300/500V(0.5mm2 - 1.0mm2) H07Z-K 450/750V (1.5mm2 - 240mm2) Testing voltage H05V...2kV;   H07V...2.5kV Conductor resistance Acc. to DIN VDE 0295 resp.   IEC 60228 Min. bending radius fixed 10 x d Min.bending radius Moved 15 x d Operating  temperature Fix ed: -30°C / +70°C Mov  ed: -5°C / + 70°C Burning behavior Self-extinguishing and flame-retardant DIN VDE0482 part 265-2-1 (IEC332/1-test-B) read more